Apollo Type 1 Double Check Detector Assembly with Left Bypass, Cubic Feet/Min Meter, OS&Y Shut-Off Valves (2 x Flange)

Scraped SKU: 4ANLF63XC3 2026-06-05 04:30:27

Attributes

Group Code4ANLF63XC3
Product Typebackflow-preventer
Brand Seriesapollo-4an-series-backflow-preventers
ApprovalsBuild America Buy America (BABA) Act, Buy American Act (BAA), Made in USA

Description

The 2-1/2” – 12” Reduced Pressure Detector Assembly shall be an Apollo® Model RPDALF4AN or RPDA2LF4AN. The assembly shall be manufactured in America and carry a 5-year Apollo® factory warranty. The normally vertical up / vertical down oriented body shall incorporate an internal swivel connection providing the ability to pivot the second check 180°, producing a vertical up RPDA assembly (2-1/2” – 8” only). The TriForceTM center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by drop-in retainers (2 1/2” – 6”) or SS studs & nuts (8” – 12”). Access to the check valves and relief valve internals shall be by an Apollo® quick-connect SS coupling (2-1/2” – 6”) or grooved couplings (covers) and SS bolts (relief valves) (8” – 12”). The bodies shall be domestic SS in 2-1/2” – 8” sizes and FDA epoxycoated ductile iron in 10” & 12” sizes. The assembly is a mainline RP with a Type 2 bypass consisting of a lead free* single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm with the mainline 2nd check remaining closed. Assemblies with the optional Type 1 bypass consist of a lead free* RP and meter which bypasses both mainline checks and accurately meters all flows up to 2 gpm with both mainline checks closed. The Apollo® domestic ball valve test cocks shall have SS handles. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are health and non-health hazards. The pressure drop across the assembly shall be documented by an independent laboratory.
  • Domestic Stainless Steel Body: 2-1/2”-8”
  • FDA Epoxy Coated Ductile Iron Body: 10” & 12”
  • Easy Maintenance: No Special Tools Required
  • Drop-In Check Retainers: 2-1/2”-6”
  • Bolted-In Checks: 8”-12”
  • Low Pressure Loss as Documented by an Independent Approval Laboratory
  • Center Stem Guided TriForce™ Check Valves
  • Modular Captured Spring Relief Valve
  • Optional Air Gap Drains
  • Small Installation Space Required - Small Footprint
  • Approved for n-Flow and Vertical Up Flow
  • Chloramine-Resistant Elastomers
  • Made in the USA (D Option)
  • Optional Valve Setters Eliminate Need for Thrust Blocks Below Grade
  • US Patent Nos.: 6,443,184; 7,025,085; 7,533,699
  • 5 Year Warranty
  • Optional Mounting of Bypass on Either Side for Ease of Installation

Variations (2)

4ANLF63AC3

size4"
dimensions-
weight268 lb
packaging-

4ANLF63CC3

size-
dimensions-
weight404 lb
packaging-

Specifications

articleApollo Type 1 Double Check Detector Assembly with Left Bypass, Cubic Feet/Min Meter, OS&Y Shut-Off Valves (2 x Flange)
article number with gtin4ANLF63XC3
manufacturerAalberts integrated piping systems Americas, Inc. (Apollo)
weight404 lb
finishingnone
product groupvalves (backflow preventers)
ETIM classEC011469 Check valve
brandApollo
series4AN Series Backflow Preventers
product type4ANLF63XC3
ETIM
{"etim-class":"EC011469 Check valve","Surface protection":"Untreated","Height":"","Height (imperial)":"","FM quality mark":"No","UL quality mark":"No","ULC quality mark":"No","LPCB quality mark":"No","Suitable for central heating water":"No","Certified according to SVGW for water":"No","Certified according to SVGW for gas":"No","VdS quality mark":"No","DVGW quality mark for gas":"No","DVGW quality mark for water":"No","KIWA certified":"No"}